Parla con un Esperto

Technical Support

DSO5052A 5000 Series Oscilloscope: 500 MHz, 2 channels [Discontinued]

Product Status: Discontinued | Currently Supported
Supported Until: 1 March 2018

View Product Details

Current Firmware/Software

Version: 1.2
Release Date: 2013-04-28

Refine the List

By Type of Content

1-25 of 38

Sort:
Evaluating Oscilloscope Fundamentals - Application Note
We will discuss oscilloscope applications and give you an overview of basic measurements and performance characteristics.

Application Note 2013-03-06

InfiniiVision 5000 Series Portable Oscilloscope
Agilent 5000 Series Portable Oscilloscopes with MegaZoom III deep memory and fast update rates help you find the bugs that you don't know about.

Data Sheet 2012-12-03

InfiniiVision Oscilloscope Probes and Accessories
To get the most out of your oscilloscope, you need the right probes and accessories. That’s why Agilent offers a complete family of innovative probes and accessories for InfiniiVision oscilloscopes.

Data Sheet 2012-11-27

Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity
Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity: How to Make the Most Accurate Digital Measurements When you select an oscilloscope for accurate, high-speed digital measurements, sampling fidelity can often be more important than maximum sample rate.

Application Note 2012-11-11

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details
The quality of your oscilloscope's display can make a big difference in your ability to troubleshoot your designs effectively.

Application Note 2012-11-08

Evaluating Oscilloscope Bandwidths for your Application
This application note provides some helpful hints on how to select an oscilloscope with the appropriate bandwidth for analog and digital applications.

Application Note 2012-11-08

Oscilloscope Mask Testing for Six Sigma Quality Standards - Application Note
This application note discusses the statistical principles that apply to the QA process and the evolution of Six Sigma efficiency-defined as achieving a defect rate of 3.4 per million or less.

Application Note 2012-11-07

Ten things to Consider when Selecting your Next Oscilloscope - Application Note
You rely on your oscilloscope every day, so selecting the right one to meet your needs is an important task. Comparing specs and features of scopes made by different manufacturers can be time-consuming and confusing. The concepts outlined here are intended to speed your selection process and help you avoid some common pitfalls. No matter who makes the scopes you are considering, carefully analyzing each one in relation to the 10 issues discussed here will help you evaluate the instruments objectively.

Application Note 2012-05-15

InfiniiVision 5000/6000/7000A Series Oscilloscopes User's Guide
This is the user's guide for the Agilent InfiniiVision 5000/6000/7000 Series oscilloscopes.

User Manual 2011-03-01

PDF PDF 13.72 MB
Evaluating Oscilloscopes for Best Waveform Update Rates
Agilent Technologies Mixed signal oscilloscopes (MSOs) have become the tool-of-choice for many of today's designers of embedded devices.

Application Note 2011-02-15

Evaluating Oscilloscopes to Debug Mixed-Signal Designs
This paper begins by defining mixed signal oscilloscopes, including an overview of the primary applications where MSOs should be used.

Application Note 2011-02-15

5000 Series Oscilloscopes Programmer's Guide
This is a zipped Microsoft Windows® format help file. Extract this file to a Local Disk (a Windows security requirement); on Windows XP, you may have to open the file's Properties dialog and Unblock the file before opening.

Programming and Syntax Guide 2010-06-30

Evaluating Oscilloscope Vertical Noise Characteristics
Measurement system noise will degrade your actual signal measurement accuracy, especially when you are measuring low-level signals and noise.

Application Note 2010-06-30

5000 Series Oscilloscopes Programmer's Guide (PDF Version)
This is a printable PDF version of the 5000 Series Oscilloscopes Programmer's Guide.

Programming and Syntax Guide 2010-06-30

Data Logging and Digitizing Using a Digital Multimeter
This measurement tip describes the use of a digital multimeter for data logging and digitizing.

Data Sheet 2010-06-24

Using an Agilent 6000 Series MSO To Debug an Automotive CAN Bus
To improve efficiency of system communication and to reduce cost, all of today's automotive designs employ a variety of serial bus communication protocols.

Application Note 2010-06-07

InfiniiVision Application-Specific Software Quick Fact Sheet
An overview of Agilent InfiniiVision application-specific software

Promotional Materials 2010-02-28

PDF PDF 250 KB
Easy Scope Program
Rent-to-own with TRS-RenTelco’s Easy Scope/ Easy Trade program

Brochure 2009-06-23

5000 Series Oscilloscopes Service Guide
This is the service guide for the 5000 Series oscilloscopes.

Service Manual 2009-06-01

PDF PDF 5.41 MB
Mixed Analog & Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope
Using a mixed analog and digital 32 bit WLAN application example, this note shows how an MSO with deep memory makes debugging today’s mixed analog and digital designs easier than ever before.

Application Note 2009-06-01

Debugging Serial Bus Systems with a Mixed-Signal Oscilloscope - AN 1395
This application note is for digital designers in R&D working with both analog and digital components, including microcontrollerand DSP systems using serial buses. also discusses the challenges associated with and new solutions for debugging.

Application Note 2009-03-13

Agilent's latest Scopes family
Scopes family flyer June 2008

Brochure 2008-06-01

PDF PDF 372 KB
Making High-Resolution Frequency Measurements with Agilent 6000 Series
Oscilloscope users often need to make higher-resolution frequency measurements than their conventional oscilloscope is designed to handle.

Application Note 2008-04-03

5000 Series- See it all together
Deep memory and fast update rate shows you more of a complex signal

Demo 2008-03-28

WMF WMF 23.23 KB
5000 Series- More connectivity options
See all of the connectivity options for the 5000 Series scope

Demo 2008-03-28

WMF WMF 6.52 MB

1 2 Next